SOP for Tap Density Testing in Powders

SOP for Tap Density Testing in Powders

Standard Operating Procedure for Tap Density Testing in Powders

1) Purpose

The purpose of this SOP is to outline the procedure for determining the tap density of powder formulations in the pharmaceutical industry to ensure consistency and quality.

2) Scope

This SOP applies to all personnel involved in tap density testing of powder formulations within the pharmaceutical quality control (QC) department.

3) Responsibilities

Analytical Chemist: Responsible for performing tap density testing and documenting results.
Quality Assurance (QA) Department: Responsible for reviewing and approving the tap density testing procedure and results.

4) Procedure

  1. Sample Preparation:
    1. Select a representative sample of the powder formulation according to sampling plan.
    2. Ensure the sample is free-flowing and not compacted.
  2. Apparatus Setup:
    1. Calibrate the tap density apparatus using a standard calibration weight.
    2. Set the apparatus to the specified number of taps per cycle.
  3. Testing:
    1. Fill the measuring cylinder with the sample to a specified volume.
    2. Secure the cylinder in the apparatus and initiate the tapping process.
    3. Continue tapping until a consistent volume is achieved (no further volume change).
  4. Measurement:
    1. Measure and record the tapped volume and mass of the sample.
    2. Calculate tap density using the formula: Tap Density = Mass of Sample / Tapped Volume.
  5. Reporting:
    1. Record the tap density measurement in the appropriate logbook or electronic system.
    2. Document any deviations or issues encountered during testing.
  6. Documentation:
    1. Maintain accurate records of all tap density testing activities, including raw data, calculations, and reports.
    2. File documentation in accordance with Good Documentation Practices (GDP).
See also  SOP for Freeze Drying in Powders Production

5) Abbreviations, if any

SOP: Standard Operating Procedure
QC: Quality Control
QA: Quality Assurance
GDP: Good Documentation Practices

6) Documents, if any

Tap Density Testing Protocol, Test Results, Tap Density Report

7) Reference, if any

Pharmacopeial guidelines for tap density testing of pharmaceutical powders.

8) SOP Version

Version 1.0