SOP for Desiccator

SOP for Desiccator

Standard Operating Procedure for Using Desiccator

1) Purpose

The purpose of this SOP is to describe the procedure for the proper use and maintenance of the desiccator in the pharmaceutical manufacturing of otic dosage forms to ensure the proper storage and protection of moisture-sensitive materials.

2) Scope

This SOP applies to all personnel involved in the use and maintenance of desiccators in the pharmaceutical manufacturing facility.

3) Responsibilities

Operators: Responsible for correctly using the desiccator as per this SOP.
Quality Control (QC) Personnel: Responsible for monitoring conditions inside the desiccator.
Maintenance Personnel: Responsible for maintaining the desiccator in proper working condition.

See also  SOP for Ultrasonic Cleaner

4) Procedure

4.1 Preparation
4.1.1 Inspection
4.1.1.1 Inspect the desiccator for cleanliness and integrity before use.
4.1.1.2 Ensure the desiccant or drying agent is sufficient and effective.

4.1.2 Loading Samples
4.1.2.1 Place moisture-sensitive materials or samples inside the desiccator.
4.1.2.2 Ensure items are placed on appropriate racks or trays to allow for proper air circulation.
4.1.2.3 Close the desiccator lid tightly to maintain low humidity levels.

4.2 Operation
4.2.1 Monitoring
4.2.1.1 Monitor the humidity levels inside the desiccator using a hygrometer or humidity indicator.
4.2.1.2 Check and replace desiccant as needed to maintain optimal conditions.
4.2.1.3 Record humidity readings regularly in the desiccator log.

See also  SOP for Blister Packing Machine

4.2.2 Accessing Samples
4.2.2.1 Open the desiccator lid only when necessary and for brief periods to minimize humidity fluctuations.
4.2.2.2 Handle samples carefully to avoid introducing moisture into the desiccator.
4.2.2.3 Close the lid securely after accessing samples to restore low humidity conditions.

4.3 Maintenance
4.3.1 Cleaning
4.3.1.1 Clean the desiccator interior regularly to remove dust and contaminants.
4.3.1.2 Wipe the desiccator seals and surfaces with a clean, dry cloth.
4.3.1.3 Inspect and replace desiccant or drying agents according to manufacturer recommendations.

4.3.2 Calibration
4.3.2.1 Calibrate the hygrometer or humidity indicator used to monitor desiccator conditions.
4.3.2.2 Verify calibration records and adjust settings if necessary.
4.3.2.3 Document all maintenance and calibration activities in the desiccator log.

See also  SOP for Compounder

5) Abbreviations, if any

QC: Quality Control
SOP: Standard Operating Procedure

6) Documents, if any

Desiccator log
Maintenance log

7) Reference, if any

Manufacturer’s manual for the desiccator
Regulatory guidelines for storage of moisture-sensitive materials in pharmaceutical manufacturing

8) SOP Version

Version 1.0