SOP for Heating Mantle

SOP for Heating Mantle

Standard Operating Procedure for Heating Mantle

1) Purpose

The purpose of this SOP is to describe the procedure for the proper operation and maintenance of the Heating Mantle used in the pharmaceutical manufacturing of otic dosage forms to ensure accurate and safe heating of substances.

2) Scope

This SOP applies to all personnel involved in the operation and maintenance of the Heating Mantle in the pharmaceutical manufacturing facility.

3) Responsibilities

Operators: Responsible for correctly operating the Heating Mantle as per this SOP.
Quality Control (QC) Personnel: Responsible for monitoring the temperature and quality of heating processes.
Maintenance Personnel: Responsible for maintaining the Heating Mantle in proper working condition.

See also  SOP for Calibration and Maintenance of Equipment

4) Procedure

4.1 Pre-operation Checks
4.1.1 Inspection
4.1.1.1 Inspect the Heating Mantle for cleanliness and integrity before use.
4.1.1.2 Ensure the heating element and insulation are intact.
4.1.1.3 Verify that all electrical connections are secure and functional.

4.1.2 Preparation
4.1.2.1 Clean the heating mantle surface.
4.1.2.2 Place the heating mantle on a stable, heat-resistant surface.
4.1.2.3 Connect the heating mantle to a power source and temperature controller.

4.2 Operation

4.2.1 Starting the Heating Mantle
4.2.1.1 Turn on the power switch and set the desired temperature on the controller.
4.2.1.2 Allow the heating mantle to reach the set temperature gradually.
4.2.1.3 Monitor the temperature closely during heating.

See also  SOP for Crimping Machine

4.2.2 Heating Process
4.2.2.1 Place the vessel or container containing the substance to be heated on the mantle.
4.2.2.2 Ensure the vessel is stable and centered on the mantle.
4.2.2.3 Adjust the temperature settings as needed to maintain the desired heating rate.
4.2.2.4 Avoid overheating and ensure safe handling of heated substances.

4.2.3 Cooling Down
4.2.3.1 Gradually reduce the temperature setting after heating is complete.
4.2.3.2 Allow the heating mantle to cool down completely before cleaning or storage.
4.2.3.3 Disconnect the heating mantle from the power source.

4.3 Post-operation
4.3.1 Maintenance
4.3.1.1 Clean the heating mantle surface and check for any residue.
4.3.1.2 Inspect the electrical connections and insulation regularly.
4.3.1.3 Store the heating mantle in a dry and safe place after use.

See also  SOP for Microfiltration Unit

5) Abbreviations, if any

QC: Quality Control
SOP: Standard Operating Procedure

6) Documents, if any

Batch records for each heating batch
Maintenance records
Calibration records for temperature controller

7) Reference, if any

Manufacturer’s manual for the Heating Mantle
Pharmacopeial guidelines for pharmaceutical heating processes

8) SOP Version

Version 1.0

Related Posts