SOP for Spray Drying for Nasal Powder Formulations




SOP for Spray Drying for Nasal Powder Formulations



Standard Operating Procedure for Spray Drying for Nasal Powder Formulations

1) Purpose

The purpose of this SOP is to outline the process for using spray drying techniques to prepare nasal powder formulations, ensuring uniform particle size and optimal drug delivery.

2) Scope

This SOP applies to all personnel involved in the spray drying process for nasal powder formulations at [Company Name].

3) Responsibilities

  • Operators: Responsible for operating the spray dryer and ensuring correct parameters are followed.
  • QA: Verifies that the powder meets the required specifications for particle size and uniformity.

4) Procedure

4.1 Equipment Setup

4.1.1 Spray Dryer Inspection

  • Inspect the spray dryer to ensure it is clean and ready for use.
  • Check that the nozzles and other components are correctly installed.
See also  SOP for Stability Studies of Nasal Formulations

4.1.2 Calibration

  • Calibrate the spray dryer according to the manufacturer’s specifications.

4.2 Solution Preparation

4.2.1 Dissolving and Mixing

  • Dissolve the API and excipients in purified water or another suitable solvent.
  • Ensure that the solution is homogenous before feeding it into the spray dryer.

4.3 Spray Drying Process

4.3.1 Process Parameters

  • Set the spray dryer to the appropriate parameters, including inlet temperature, outlet temperature, and feed rate.
  • Start the spray drying process, ensuring that the feed solution is atomized properly into the drying chamber.

4.3.2 Monitoring

  • Monitor the spray drying process continuously to ensure consistent particle size and drying.
  • Make adjustments as necessary to the feed rate, air flow, and temperature to optimize the drying process.
See also  SOP for Maintenance of Cleanroom Facilities

4.4 Post-Spray Drying Testing

4.4.1 Particle Size Analysis

  • After spray drying, collect a sample of the powder and test the particle size distribution using a particle size analyzer.

4.4.2 Moisture Content Testing

  • Test the moisture content of the powder to ensure it meets the target specifications.

4.5 Packaging

4.5.1 Powder Collection

  • Collect the spray-dried powder into sterilized containers.

4.5.2 Storage

  • Store the collected powder in a controlled environment to maintain its stability.

4.6 Documentation

  • Document all process steps, including the parameters used, particle size, and moisture content, in the batch manufacturing record (BMR).

5) Abbreviations, if any

  • API: Active Pharmaceutical Ingredient
  • QA: Quality Assurance
  • BMR: Batch Manufacturing Record
See also  SOP for Handling and Operation of Microbial Testing Equipment

6) Documents, if any

  • Batch Manufacturing Record (BMR)
  • Particle Size and Moisture Content Log

7) References, if any

  • FDA Guidance for Industry – Nasal Drug Products

8) SOP Version

Version 1.0

Annexure

Particle Size and Moisture Content Log Template

Date Formulation Particle Size Range (µm) Moisture Content (%) Operator Initials QA Approval
DD/MM/YYYY Formulation Name Size Range Moisture Operator Name QA Name
           