Procedure for Optimizing Ointment Viscosity Parameters
Department | Research and Development (R&D)/Quality Control |
---|---|
SOP No. | FD-016 |
Supersedes | V 1.0 |
Page No. | Page X of Y |
Issue Date | [Insert Issue Date] |
Effective Date | [Insert Effective Date] |
Review Date | [Insert Review Date] |
1. Purpose
The purpose of this Standard Operating Procedure (SOP) is to establish a standardized process for optimizing viscosity parameters in ointments. Proper viscosity ensures ease of application, spreadability, and uniform drug delivery, thereby maintaining product efficacy and stability.
2. Scope
This SOP applies to the Research and Development (R&D) and Quality Control (QC) departments responsible for determining, adjusting, and optimizing the viscosity of ointments during formulation development and manufacturing.
3. Responsibilities
- Formulation Scientist: Develops and adjusts viscosity parameters for different ointment formulations.
- Quality Control (QC) Analyst: Conducts viscosity testing and verifies compliance with product specifications.
- Quality Assurance (QA) Personnel: Ensures compliance with standard procedures and regulatory guidelines.
- R&D Head: Reviews and approves viscosity optimization reports before finalizing formulations.
4. Accountability
The R&D and QC Managers are accountable for ensuring that viscosity optimization is conducted as per regulatory and quality standards.
5. Procedure
5.1 Selection of Ointment Formulation Components
- Identify the base components, including oils, waxes, and emulsifiers.
- Select appropriate gelling and thickening agents.
- Ensure that all raw materials comply with pharmacopeial standards (USP, BP, IP).
5.2 Initial Viscosity Assessment
- Prepare an initial batch of ointment based on the proposed formulation.
- Measure viscosity using a Brookfield Viscometer or equivalent equipment.
- Document initial viscosity values in the Viscosity Optimization Log.
5.3 Adjustment of Viscosity Parameters
- If viscosity is too high:
- Increase the proportion of liquid components (e.g., oils, solvents).
- Reduce the concentration of thickening agents.
- Adjust processing parameters such as mixing speed and temperature.
- If viscosity is too low:
- Increase the concentration of thickening or gelling agents.
- Reduce the amount of liquid excipients.
- Modify cooling rates to enhance consistency.
5.4 Rheological Testing
- Measure viscosity at different shear rates to assess shear-thinning or thixotropic behavior.
- Perform oscillatory rheometry to evaluate viscoelastic properties.
- Compare test results with target viscosity specifications.
5.5 Spreadability Testing
- Apply a standard weight to a 1 g sample of ointment placed between two glass slides.
- Measure the diameter of the spread sample.
- Ensure spreadability falls within the acceptable range for topical application.
5.6 Stability Testing
- Store optimized formulations under different conditions:
- 25°C ± 2°C / 60% RH
- 40°C ± 2°C / 75% RH
- Refrigerated conditions (2-8°C)
- Monitor viscosity over time to ensure long-term stability.
- Document any changes in the Stability Testing Report.
5.7 Documentation and Reporting
- Record all viscosity test results in the Viscosity Optimization Log.
- Summarize findings in the Viscosity Optimization Report.
- Obtain approval from the R&D Head and QA before finalizing viscosity parameters.
6. Abbreviations
- QC – Quality Control
- QA – Quality Assurance
- USP – United States Pharmacopeia
- BP – British Pharmacopeia
- IP – Indian Pharmacopeia
- RH – Relative Humidity
7. Documents
- Viscosity Optimization Log (Annexure-1)
- Viscosity Optimization Report (Annexure-2)
8. References
- USP <911> Viscosity Guidelines
- ICH Q1A (R2) Stability Testing Guidelines
- WHO GMP Guidelines for Pharmaceutical Manufacturing
- 21 CFR Part 211 – Current Good Manufacturing Practices
9. SOP Version
Version 2.0
10. Approval Section
Prepared By | Checked By | Approved By | |
---|---|---|---|
Signature | |||
Date | |||
Name | |||
Designation | |||
Department |
11. Annexures
Annexure-1: Viscosity Optimization Log
Date | Batch Number | Test Parameter | Specification | Result | Verified By |
---|---|---|---|---|---|
01/02/2025 | OINT-001 | Viscosity (cP) | 1000-2000 | 1500 | QA Officer |
02/02/2025 | OINT-002 | Spreadability (mm) | 5-10 | 7 | QA Officer |
Annexure-2: Viscosity Optimization Report
Date | Batch Number | Parameter Adjusted | Adjustment Method | Final Viscosity (cP) | Final Status |
---|---|---|---|---|---|
01/02/2025 | OINT-001 | Thickening Agent | Increased concentration | 1800 | Pass |
02/02/2025 | OINT-002 | Oil Content | Reduced quantity | 1200 | Pass |
12. Revision History:
Revision Date | Revision No. | Details of Revision | Reason for Revision | Approved By |
---|---|---|---|---|
01/01/2024 | 1.0 | Initial Version | New SOP | QA Head |
01/02/2025 | 2.0 | Updated SOP Format | Standardization of Document | QA Head |