Aerosol: SOP for Developing Analytical Methods for Aerosols – V 2.0

Aerosol: SOP for Developing Analytical Methods for Aerosols – V 2.0

SOP for Developing Analytical Methods for Aerosols

Department Aerosol
SOP No. SOP/Aerosol/013/2025
Supersedes SOP/Aerosol/013/2022
Page No. Page 1 of Y
Issue Date 06/02/2025
Effective Date 16/02/2025
Review Date 06/02/2028

1. Purpose

This Standard Operating Procedure (SOP) describes the process for developing analytical methods for aerosol products. It provides guidelines for selecting, developing, validating, and implementing analytical techniques to assess the quality and performance of aerosol formulations in accordance with Good Manufacturing Practices (GMP) and regulatory standards.

2. Scope

This procedure applies to all personnel involved in the development of analytical methods for aerosol products at [Company Name]. It includes the selection and validation of methods for testing raw materials, in-process formulations, and finished aerosol products. This SOP does not apply to the manufacturing or packaging processes themselves.

3. Responsibilities

4. Accountability

The Research and Development (R&D) Manager is accountable for ensuring that this SOP is followed during the development of analytical methods for aerosol products. The overall compliance to this SOP is under the supervision of the Quality Assurance (QA) Manager.

5. Procedure

5.1. Analytical Method Selection

  1. Identify the key quality attributes of the aerosol product, such as active ingredient concentration, propellant content, particle size, and delivery performance.
  2. Based on these attributes, select the appropriate analytical methods, such as High-Performance Liquid Chromatography (HPLC), gas chromatography (GC), spectroscopy, or particle size analysis, considering the type of aerosol product and regulatory requirements.
  3. Ensure that selected methods are suitable for the matrix, stability, and sensitivity of the aerosol product. Consider factors such as the detection limit, accuracy, and precision of the method.

5.2. Method Development

  1. Develop the analytical method by performing experiments to optimize parameters such as sample preparation, solvent selection, and instrumental conditions. This step should ensure that the method is robust and capable of delivering reliable, reproducible results.
  2. Perform method trials to evaluate the analytical performance of the method under different conditions. Collect data on precision, accuracy, specificity, and sensitivity.
  3. Document the results of method development, including the conditions used, calibration curves, validation data, and initial method performance. This should be recorded in the Method Development Log (Annexure-1).

5.3. Method Validation

  1. Validate the developed analytical method following standard validation protocols. The validation should include the following parameters:
    • Specificity: The ability to measure the analyte in the presence of other components.
    • Precision: The repeatability of the method under normal operating conditions.
    • Accuracy: The closeness of the measured value to the true value or standard.
    • Linearity: The ability to obtain test results that are directly proportional to the concentration of the analyte.
    • Detection Limit: The lowest quantity of the analyte that can be reliably detected.
    • Range: The interval between the upper and lower concentration limits of the analyte that the method can accurately measure.
  2. Prepare a Method Validation Report (Annexure-2) summarizing the validation results, including the methodology, equipment used, validation parameters, and conclusions. The report should be reviewed and approved by the QC team and regulatory affairs team.

5.4. Method Implementation

  1. Once validated, the analytical method should be transferred to the QC laboratory for routine use in testing raw materials, in-process samples, and finished aerosol products.
  2. Train the laboratory personnel on the method’s use, and ensure that all testing equipment is calibrated and functioning according to the specified requirements.
  3. Document the implementation process in the Method Transfer Report (Annexure-3), including any adjustments or improvements made during the transfer.

5.5. Ongoing Method Monitoring and Review

  1. Once implemented, continuously monitor the method’s performance during routine testing. Periodically review the method’s ability to meet the specified quality attributes, and compare the results with historical data.
  2. If the method performance deviates from expectations (e.g., loss of precision or accuracy), initiate corrective actions, such as equipment calibration, retraining of personnel, or adjustment of method parameters.
  3. Regularly review the method to ensure that it remains compliant with current regulatory standards and any updates in industry practices.

5.6. Corrective and Preventive Actions (CAPA)

  1. If issues arise during method validation or implementation (e.g., method failure, inconsistency in results), initiate corrective actions to resolve the issue. This may involve revising the method, conducting additional training, or adjusting testing procedures.
  2. Implement preventive actions to avoid recurrence, such as improving the method development process, ensuring better training for personnel, or enhancing equipment maintenance.
  3. Document all corrective and preventive actions in the CAPA Log (Annexure-4) and track the effectiveness of the actions taken.

6. Abbreviations

7. Documents

  1. Method Development Log (Annexure-1)
  2. Method Validation Report (Annexure-2)
  3. Method Transfer Report (Annexure-3)
  4. CAPA Log (Annexure-4)

8. References

This SOP is based on the following regulatory guidelines and industry standards:

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Method Development Log

Test Parameter Test Method Initial Results Adjustments Made Test Date
Active Ingredient HPLC Pass Adjusted column temperature 06/02/2025

Annexure-2: Method Validation Report

Method Validation Parameter Result Test Date Tested By
HPLC Method Accuracy Pass 06/02/2025 Rajesh Patel

Annexure-3: Method Transfer Report

Method Name Transfer Date Testing Results Transferred By Comments
HPLC Method 06/02/2025 Pass Ravi Kumar Successfully transferred

Annexure-4: CAPA Log

Issue Root Cause Corrective Action Preventive Action Follow-up Date
Method precision failure Improper calibration Recalibrated equipment Regular calibration checks 06/03/2025

12. Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By Page No. Ref. Point No. Details of Revision
01/01/2024 V 1.0 Initial Release First Issue Anjali Sharma Page 1 [Ref Point] First Release
01/01/2025 V 2.0 Updated method validation and implementation processes To comply with updated GMP regulations Anjali Sharma Page 1 [Ref Point] Updated procedures