Standard Operating Procedure for API and Excipient Compatibility Studies

Department Capsule Manufacturing
SOP No. SOP/CM/022/2025
Supersedes SOP/CM/022/2022
Page No. Page 1 of 6
Issue Date 01/02/2025
Effective Date 05/02/2025
Review Date 01/02/2026

1. Purpose

This SOP defines the procedure for conducting compatibility studies between active pharmaceutical ingredients (APIs) and excipients to ensure that no interactions or incompatibilities affect the performance, stability, or safety of the final capsule formulation.

2. Scope

This SOP applies to all compatibility studies between APIs and excipients during capsule formulation development. The studies ensure the suitability of excipients for a stable and effective capsule formulation.

3. Responsibilities

4. Accountability

The Formulation Development Supervisor is accountable for ensuring that all compatibility studies are conducted as per the SOP. The QA Manager is responsible for ensuring that all procedures are followed and that results are properly documented and reviewed.

5. Procedure

5.1 Selection of API and Excipients

Ensure that appropriate APIs and excipients are selected for compatibility testing:

  1. API Selection
    1. Select an API based on its pharmacological properties, solubility, stability, and compatibility with potential excipients.
    2. Ensure that the API is available in sufficient quantities and is compatible with common excipients in capsule formulations.
  2. Excipient Selection
    1. Select excipients such as fillers, binders, disintegrants, lubricants, and stabilizers based on their functionality and compatibility with the API.
    2. Ensure that excipients have a good safety profile and meet regulatory standards.

5.2 Conducting API and Excipient Compatibility Testing

Perform compatibility studies between the API and excipients to identify potential interactions:

  1. Physical Compatibility Testing
    1. Mix the API with each excipient in the formulation to observe any physical changes such as color change, phase separation, or precipitation.
    2. Monitor and document any changes in appearance, texture, or consistency that may indicate incompatibility.
  2. Chemical Compatibility Testing
    1. Perform analytical tests such as FTIR (Fourier Transform Infrared Spectroscopy), HPLC (High-Performance Liquid Chromatography), or DSC (Differential Scanning Calorimetry) to assess chemical interactions between the API and excipients.
    2. Analyze the results for any chemical degradation or formation of new compounds that may affect the API’s stability or effectiveness.
  3. Stability Studies
    1. Subject the API-excipient mixture to accelerated stability testing at high temperature and humidity conditions to assess the long-term stability of the formulation.
    2. Monitor the mixture over a specific period to identify any degradation or incompatibility that could affect the final product’s quality.

5.3 Evaluating Results of Compatibility Studies

After completing the compatibility testing, evaluate the results to determine the suitability of excipients for use in the formulation:

  1. Review of Data
    1. Analyze the data from all testing methods, including physical, chemical, and stability testing, to determine if any excipients caused undesirable interactions with the API.
    2. Identify excipients that show no signs of incompatibility or degradation, and select them for use in the formulation.
  2. Document Results
    1. Document all findings from the compatibility studies, including test methods, results, and recommendations for excipient selection.
    2. Ensure that all documentation is reviewed and signed off by the Formulation Development and QA teams.

5.4 Adjusting Formulation Based on Compatibility Results

If any incompatibilities are identified during the compatibility studies, take corrective actions:

  1. Reformulation
    1. If incompatibility is observed, replace the problematic excipient with a suitable alternative that does not interfere with the API’s stability or performance.
    2. Retest the new formulation for compatibility and stability to ensure that the adjustments have resolved the issues.
  2. Formulation Optimization
    1. Optimize the final formulation by selecting excipients that maintain the API’s stability and enhance its performance, ensuring that the capsule formulation meets all required specifications.

5.5 Documentation and Record-Keeping

Ensure that all compatibility study results are well-documented and stored for future reference:

  1. Study Report
    1. Compile a comprehensive report that includes details of the API and excipient selection, the methods used for compatibility testing, results, and any formulation changes made based on the findings.
    2. Ensure that the report is reviewed and approved by the formulation team and QA team.
  2. Record Retention
    1. Ensure that all records related to the compatibility studies, including test data and reports, are securely stored and easily accessible for future reference and regulatory submissions.

6. Abbreviations

7. Documents

  1. API and Excipient Compatibility Study Report (Annexure-1)
  2. Stability Test Results (Annexure-2)
  3. API-Excipients Interaction Analysis (Annexure-3)

8. References

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: API and Excipient Compatibility Study Report

Date API Excipient Study Type Result Summary
03/02/2025 API-123 Excipient-456 FTIR, DSC No significant interactions

Annexure-2: Stability Test Results

Date Test Type Test Result Action Taken
04/02/2025 Accelerated Stability Test No degradation at 40°C and 75% RH Formulation is stable

Annexure-3: API-Excipients Interaction Analysis

Date API Excipient Interaction Type Result
03/02/2025 API-123 Excip-456 Chemical No significant interaction observed

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated compatibility study procedures Standardization and clarity QA Head