SOP Guide for Pharma

Creams: SOP for Developing Perfume Stability in Creams – V 2.0

Creams: SOP for Developing Perfume Stability in Creams – V 2.0

Standard Operating Procedure for Developing Perfume Stability in Creams

Department Creams
SOP No. SOP/CRM/031/2025
Supersedes SOP/CRM/031/2022
Page No. Page 1 of 6
Issue Date 30/07/2025
Effective Date 04/08/2025
Review Date 30/07/2026

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to establish the process for developing and evaluating perfume stability in cream formulations. Perfume stability ensures that the fragrance in the cream remains consistent, effective, and safe for use throughout the product’s shelf life, without degrading or reacting with other ingredients.

2. Scope

This SOP applies to all cream formulations that contain added perfumes or fragrances. It covers the process of selecting, developing, and testing fragrance stability to ensure that the final product meets customer expectations in terms of scent, safety, and shelf life.

3. Responsibilities

4. Accountability

The Head of Creams Manufacturing is responsible for overseeing the development of perfume stability in cream formulations. The QA Manager is accountable for ensuring that fragrance stability testing is conducted in compliance with regulatory and internal standards.

5. Procedure

5.1 Selection of Fragrance Components

  1. Select the fragrance components based on the product’s intended use, target market, and desired sensory characteristics (e.g., floral, citrus, etc.).
  2. Ensure that the selected fragrance is compatible with the cream formulation and will not interfere with the cream’s texture, color, or stability.
  3. Obtain safety and regulatory documentation for the selected fragrance ingredients, including safety data sheets (SDS) and compliance with relevant fragrance regulations.

5.2 Incorporating Fragrance into the Cream Formulation

  1. Add the fragrance to the cream formulation in the appropriate concentration, following formulation specifications. The concentration should be based on both desired sensory characteristics and regulatory guidelines.
  2. Blend the fragrance thoroughly into the cream formulation to ensure uniform distribution. Use appropriate mixing techniques to avoid any fragrance instability or degradation during the mixing process.

5.3 Perfume Stability Testing

  1. Conduct stability tests to evaluate how the fragrance holds up over time. The testing should include:
    • Real-Time Stability Testing: Store samples of the cream formulation with fragrance under normal storage conditions and monitor the fragrance over time.
    • Accelerated Stability Testing: Expose samples to extreme conditions such as high temperatures or light to simulate prolonged storage and observe any changes in the fragrance.
    • Oxidative Stability: Assess the fragrance’s resistance to oxidation, which can cause the scent to degrade or change.
  2. Test fragrance stability at various stages of the product’s shelf life (e.g., 1 month, 3 months, 6 months) to determine any loss of fragrance strength or alteration in scent.
  3. Record any observations regarding changes in the fragrance, including fading, alteration of scent, or the development of off-odors.

5.4 Analytical Testing of Fragrance Stability

  1. Conduct analytical tests to assess any chemical changes in the fragrance components over time. These tests may include:
    • Gas Chromatography (GC): Used to analyze the composition of fragrance components and detect any degradation products.
    • Headspace Analysis: Measures volatile components of the fragrance to determine any evaporation or loss of fragrance over time.
    • Color and pH Testing: Ensures that the fragrance has not caused any unwanted color changes or alterations in the cream’s pH.
  2. Compare the test results from the fragrance stability studies to the initial test results to evaluate any significant changes in the composition or sensory properties.

5.5 Documentation of Perfume Stability Results

  1. Document all stability testing results, including:
    • The testing conditions (e.g., temperature, light exposure)
    • The initial and final fragrance characteristics
    • Test results from analytical methods (e.g., GC, headspace analysis)
    • Any deviations or changes observed during stability testing
  2. Prepare a Perfume Stability Report (Annexure-1) that includes all findings and conclusions. The report should clearly state whether the fragrance remains stable throughout the product’s shelf life and whether it meets the product’s quality standards.
  3. Submit the Perfume Stability Report for review and approval by the QA team before proceeding to commercialization.

5.6 Final Approval and Commercialization

  1. Once the perfume stability tests are completed and the results are satisfactory, finalize the product formulation for commercial production.
  2. Ensure that all regulatory submissions related to the fragrance are completed and that the fragrance complies with all safety and regulatory standards for cosmetic products.
  3. Document the final formulation and all related stability testing in the product development files.

6. Abbreviations

7. Documents

  1. Perfume Stability Report (Annexure-1)
  2. Formulation Development Log (Annexure-2)
  3. Stability Testing Log (Annexure-3)

8. References

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Perfume Stability Report

Test Type Initial Fragrance Final Fragrance Test Date Result
Real-time Stability Floral Floral (No Change) 25/07/2025 Pass

Annexure-2: Formulation Development Log

Formulation Name Batch Number Ingredients Fragrance Fragrance Test Results
Moisturizing Cream 67890 Water, Glycerin, Hyaluronic Acid Rose Pass (Stability over 6 months)

Annexure-3: Stability Testing Log

Test Type Test Date Fragrance Observations Approval Status
Oxidative Stability 12/07/2025 No degradation or off-odors Approved

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/03/2024 1.0 Initial Version New SOP Creation QA Head
01/03/2025 2.0 Format Revision and Updates Standardization of Document QA Head
Exit mobile version