SOP for Cleaning and Maintenance of Sieving Equipment

Posted on By

Standard Operating Procedure (SOP) for Cleaning & Maintenance of Sieving Equipment

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to provide guidelines for the effective cleaning and maintenance of sieving equipment in order to ensure optimal performance, prevent contamination, and maintain the quality of pharmaceutical products.

2. Scope

This SOP applies to all personnel involved in the cleaning and maintenance of sieving equipment within the pharmaceutical company.

3. Responsibilities

  • The Quality Assurance (QA) department is responsible for implementing and maintaining this SOP.
  • The Production department is responsible for performing the cleaning and maintenance tasks.
See also  SOP for Sieve Replacement and Calibration

4. Procedure

The following steps outline the procedure for the cleaning and maintenance of sieving equipment:

4.1. Cleaning

  1. Switch off the sieving equipment and disconnect the power supply before starting the cleaning process.
  2. Wear appropriate personal protective equipment (PPE) such as gloves and safety glasses.
  3. Remove any remaining material from the sieves and collection containers using a suitable brush or vacuum cleaner.
  4. Disassemble the equipment components, such as sieves, pan, and covers, as applicable.
  5. Thoroughly clean each component using a mild detergent solution and a soft brush.
  6. Rinse all the components with clean water to remove any detergent residue.
  7. Dry the components completely using lint-free cloths or by air drying.
  8. Inspect the sieves for any damages, such as tears or bent edges. Replace any damaged sieves as necessary.
  9. Reassemble the sieving equipment, ensuring that all components are properly aligned and secured.
  10. Sanitize the equipment surfaces using a suitable disinfectant to minimize the risk of microbial contamination.
See also  Quality Control, Tablet Manufacturing: SOP for Tablet Disintegration Testing:

4.2. Maintenance

  1. Regularly inspect the sieving equipment for signs of wear, malfunction, or damage.
  2. Tighten any loose bolts, screws, or fasteners to ensure stability and proper functioning.
  3. Check the electrical connections and cords for any fraying or damage.
  4. Verify that the vibration settings of the equipment are calibrated and functioning correctly.
  5. Lubricate the moving parts of the equipment, if applicable, according to the manufacturer’s recommendations.
  6. Perform routine calibration checks on the equipment to ensure accuracy.
  7. Maintain accurate and up-to-date maintenance records for the sieving equipment.

5. Abbreviations Used

  • QA: Quality Assurance
  • SOP: Standard Operating Procedure
  • PPE: Personal Protective Equipment

6. Documents

  • Sieving Equipment Cleaning Log
  • Sieving Equipment Maintenance Log
See also  SOP for Cleaning and Maintenance of Printing Equipment

7. References

No specific references are applicable for this SOP.

8. SOP Version

This is version 1.0 of the SOP for Cleaning and Maintenance of Sieving Equipment.

Tablet Manufacturing Tags:Tablet batch record review, Tablet blending SOP, Tablet cleaning and maintenance, Tablet coating procedure, Tablet compression SOP, Tablet disintegration test procedure, Tablet dissolution procedure, Tablet formulation SOP, Tablet friability testing SOP, Tablet labeling and packaging SOP, Tablet manufacturing equipment SOP, Tablet manufacturing SOP, Tablet packaging SOP, Tablet production procedure, Tablet quality control SOP, Tablet sampling and in-process testing SOP, Tablet stability testing SOP, Tablet storage and handling procedure, Tablet uniformity testing procedure, Tablet weight variation SOP

Post navigation

Previous Post: SOP for Sieve Replacement and Calibration
Next Post: SOP for Operation of Tablet Deduster

Standard Operating Procedures V 1.0

  • Aerosols
  • Analytical Method Development
  • Bioequivalence Bioavailability Study
  • Capsule Formulation
  • Clinical Studies
  • Creams
  • Data Integrity
  • Dental Dosage Forms
  • Drug Discovery
  • Environment, Health and Safety
  • Formulation Development
  • Gels
  • Good Distribution Practice
  • Good Warehousing Practices
  • In-Process Control
  • Injectables
  • Liquid Orals
  • Liposome and Emulsion Formulations
  • Lotions
  • Lyophilized Products
  • Maintenance Dept.
  • Medical Devices
  • Metered-Dose Inhaler
  • Microbiology Testing
  • Nanoparticle Formulation
  • Nasal Spray Formulations
  • Nebulizers
  • Ocular (Eye) Dosage Forms
  • Ointments
  • Otic (Ear) Dosage Forms
  • Pharmacovigilance
  • Powder & Granules
  • Purchase Departments
  • Quality Assurance
  • Quality Control
  • Raw Material Stores
  • Regulatory Affairs
  • Tablet Manufacturing
  • Rectal Dosage Forms
  • Transdermal Patches
  • Vaginal Dosage Forms
  • Validations and Qualifications

Read SOPs in your Language:

English
 - 
en
Bengali
 - 
bn
English
 - 
en
Gujarati
 - 
gu
Hindi
 - 
hi
Malayalam
 - 
ml
Marathi
 - 
mr
Punjabi
 - 
pa
Tamil
 - 
ta
Telugu
 - 
te

NEW! Revised SOPs – V 2.0

  • Aerosols V 2.0
  • API Manufacturing V 2.0
  • BA-BE Studies V 2.0
  • Capsules V 2.0
  • Creams V 2.0
  • Ointments V 2.0
  • Raw Material Warehouse V 2.0
  • Tablet Manufacturing V2.0

New Publication: A must for All.

Copyright © 2025 SOP Guide for Pharma.

Powered by PressBook WordPress theme

Go to mobile version