1) Purpose

The purpose of this SOP is to describe the procedure for the proper operation and maintenance of the cryogenic mill in the pharmaceutical manufacturing of otic dosage forms to ensure efficient size reduction of materials at ultra-low temperatures.

2) Scope

This SOP applies to all personnel involved in the operation and maintenance of cryogenic mills in the pharmaceutical manufacturing facility.

3) Responsibilities

Operators: Responsible for correctly operating the cryogenic mill as per this SOP.
Quality Control (QC) Personnel: Responsible for monitoring particle size reduction processes.
Maintenance Personnel: Responsible for maintaining the cryogenic mill in proper working condition.

4) Procedure

4.1 Pre-operation Checks
4.1.1 Inspection
4.1.1.1 Inspect the cryogenic mill for cleanliness and integrity before use.
4.1.1.2 Ensure that the mill chamber and components are free from contaminants.
4.1.1.3 Check that the mill is properly connected to the cryogenic cooling system.

4.1.2 Preparation
4.1.2.1 Ensure that the materials to be milled are suitable for cryogenic processing.
4.1.2.2 Load the materials into the mill chamber according to recommended capacity.
4.1.2.3 Connect

and verify the cryogenic cooling supply to the mill.

4.2 Operation
4.2.1 Setting the Controls
4.2.1.1 Power on the cryogenic mill and set the desired milling parameters (e.g., speed, time).
4.2.1.2 Start the milling process and monitor the particle size reduction.
4.2.1.3 Adjust the milling parameters as necessary to achieve the desired particle size.

4.2.2 Safety Precautions
4.2.2.1 Wear appropriate PPE, including cryogenic gloves and face shield, when handling cryogenic materials.
4.2.2.2 Handle milled materials carefully to prevent exposure to ambient temperature.
4.2.2.3 Follow all safety protocols for working with cryogenic equipment.

4.3 Post-operation
4.3.1 Shutdown
4.3.1.1 Stop the milling process and disconnect the cryogenic cooling supply.
4.3.1.2 Remove milled materials from the mill chamber and transfer them to appropriate containers.
4.3.1.3 Clean the mill chamber and components thoroughly to remove any residual materials.

4.3.2 Maintenance
4.3.2.1 Regularly inspect the mill chamber and components for wear and damage.
4.3.2.2 Clean and lubricate moving parts according to manufacturer guidelines.
4.3.2.3 Calibrate milling parameters and verify performance periodically.

5) Abbreviations, if any

QC: Quality Control
SOP: Standard Operating Procedure
PPE: Personal Protective Equipment

6) Documents, if any

Milling log
Maintenance records for the cryogenic mill

7) Reference, if any

Manufacturer’s manual for the cryogenic mill
Pharmacopeial guidelines for particle size reduction processes in pharmaceutical manufacturing