1) Purpose

This SOP outlines the procedures for conducting an environmental monitoring program to ensure that the manufacturing environment meets the required cleanliness and microbiological standards, ensuring the quality and safety of pharmaceutical products.

2) Scope

This SOP applies to all areas within the pharmaceutical manufacturing facility that require environmental monitoring, including cleanrooms, production areas, and other controlled environments.

3) Responsibilities

The Quality Control (QC) department is responsible for executing the environmental monitoring program. Quality Assurance (QA) is responsible for overseeing the program and ensuring compliance with this SOP and regulatory requirements.

4) Procedure

4.1 Program Design

  1. Develop an environmental monitoring plan that outlines sampling locations, frequency, and methods.
  2. Identify critical and non-critical areas that require monitoring based on risk assessment.

4.2 Sampling Methods

  1. Surface Sampling:
    1. Use contact plates or swabs to collect samples from surfaces in critical areas.
    2. Label the samples with location, date, and time of sampling.
  2. Air Sampling:
    1. Use active air samplers or settle plates to collect airborne particles and microorganisms.
    2. Place settle plates at strategic locations and expose them for a defined period.
  3. Personnel Monitoring:
    1. Use contact plates to sample gloves and gowns of personnel working in critical areas.
    2. Ensure samples are labeled with personnel ID, location, date, and time.

4.3

Sampling Schedule
  1. Conduct environmental monitoring according to the predefined schedule outlined in the environmental monitoring plan.
  2. Adjust sampling frequency based on the risk assessment and historical data trends.

4.4 Sample Handling and Incubation

  1. Transport samples to the microbiology laboratory promptly and under appropriate conditions.
  2. Incubate samples under specified conditions (e.g., temperature, duration) to allow for microbial growth.

4.5 Data Analysis

  1. Analyze incubated samples to count colony-forming units (CFUs) and identify microbial species if necessary.
  2. Compare results against predefined action and alert limits to assess environmental control.

4.6 Reporting and Documentation

  1. Document all environmental monitoring activities, including sample locations, methods, results, and any deviations.
  2. Prepare periodic summary reports to review trends and assess the overall state of environmental control.

4.7 Corrective and Preventive Actions (CAPA)

  1. Initiate CAPA procedures if results exceed action limits or show adverse trends.
  2. Implement corrective actions to address the root cause of any contamination and prevent recurrence.

5) Abbreviations, if any

SOP: Standard Operating Procedure
QA: Quality Assurance
QC: Quality Control
CFU: Colony-Forming Unit
CAPA: Corrective and Preventive Actions

6) Documents, if any

Environmental Monitoring Plan, Sampling Logs, Sample Labels, Incubation Records, Data Analysis Reports, CAPA Records

7) Reference, if any

Regulatory guidelines such as FDA Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing – Current Good Manufacturing Practice, USP <797> Pharmaceutical Compounding – Sterile Preparations, EU GMP Annex 1: Manufacture of Sterile Medicinal Products

8) SOP Version

Version 1.0