SOP Guide for Pharma

SOP for Operation of Nebulizer Sealing Machines

SOP for Operation of Nebulizer Sealing Machines

Standard Operating Procedure for Operating Nebulizer Sealing Machines

1) Purpose

The purpose of this SOP is to establish a standardized procedure for operating nebulizer sealing machines to ensure proper sealing of components and maintain product integrity.

2) Scope

This SOP applies to all nebulizer sealing machines used during the assembly and packaging process in the production facility.

3) Responsibilities

Operators: Operate sealing machines and monitor performance.
Maintenance Team: Perform routine maintenance and troubleshoot issues.
Quality Assurance (QA): Validate the sealing process and approve the output for compliance with quality standards.

4) Procedure

4.1 Pre-Operation Checks

  • Ensure the sealing machine is clean and free of any residual material or debris from previous batches.
  • Verify that all safety guards are in place and functional.
  • Inspect the machine components, including heating elements and pressure plates, for any signs of damage or wear.
  • Calibrate the machine settings, such as temperature, pressure, and sealing duration, as per the batch requirements.
  • Perform a dry run without any components to confirm the machine is functioning correctly.

4.2 Machine Operation

  • Load the components (e.g., nebulizer housings or caps) into the machine manually or via the conveyor system, ensuring proper alignment.
  • Start the sealing process by activating the control panel or foot pedal,
depending on the machine type.
  • Monitor the sealing parameters displayed on the control panel, such as temperature and pressure, throughout the operation.
  • Inspect the first few sealed components to confirm proper sealing quality before continuing with the batch.
  • 4.3 In-Process Monitoring

    • Perform random sampling at regular intervals during the sealing process to check for defects, such as incomplete seals or overheating.
    • Adjust machine settings if any deviations are observed in sealing quality.
    • Document any adjustments made in the Equipment Operation Log.

    4.4 Post-Operation Activities

    • Turn off the machine and allow it to cool before cleaning or maintenance.
    • Inspect the sealed components to ensure they meet quality standards and segregate any defective units.
    • Clean the machine as per the cleaning SOP to prevent contamination or residue buildup.
    • Record the batch details and machine performance in the logbook.

    4.5 Safety Precautions

    • Always wear personal protective equipment (PPE), including gloves and safety glasses, during operation.
    • Ensure proper grounding of the machine to avoid electrical hazards.
    • Do not touch the heating elements or pressure plates while the machine is operational.

    5) Abbreviations

    • QA: Quality Assurance
    • PPE: Personal Protective Equipment

    6) Documents

    The following documents should be maintained:

    • Equipment Operation Log
    • Batch Sealing Report
    • Sealing Defect Log

    7) References

    Relevant regulatory guidelines and references include:

    • ISO 13485: Medical Devices Quality Management Systems
    • Equipment Manufacturer’s Manual

    8) SOP Version

    Version: 1.0

    Annexure

    Annexure Title: Equipment Operation Log

     
    Date Machine ID Batch No. Parameters Set Operator Initials Remarks
    DD/MM/YYYY Machine Identifier Batch Number Temperature, Pressure, Time Operator Name Details of operation
               

    Annexure Title: Batch Sealing Report

     
    Date Batch No. Sealed Units Defective Units QA Approval Remarks
    DD/MM/YYYY Batch Number Number of Units Number of Units QA Name Details of batch
               

    Annexure Title: Sealing Defect Log

     
    Date Batch No. Defect Type Operator Initials Action Taken Remarks
    DD/MM/YYYY Batch Number Defect Description Operator Name Correction/Rework Details of defect
               
    Exit mobile version