1) Purpose

The purpose of this Standard Operating Procedure (SOP) is to define the process for validating detergents and cleaning agents used in pharmaceutical manufacturing. This SOP ensures that detergents and cleaning agents are properly validated to confirm their efficacy in removing residues of active pharmaceutical ingredients (APIs), excipients, cleaning agents, and microbial contaminants from manufacturing equipment. The cleaning agents must be verified to meet the required standards for cleaning effectiveness and safety in the manufacturing environment, ensuring compliance with regulatory standards.

2) Scope

This SOP applies to the validation of detergents and cleaning agents used in pharmaceutical manufacturing processes, including cleaning validation of manufacturing equipment, filling machines, and packaging machinery. The validation process includes assessing the detergents’ and cleaning agents’ ability to remove residues and contaminants from surfaces effectively. This SOP applies to new detergents and cleaning agents, as well as those that have been reformulated or changed. It ensures compliance with good manufacturing practices (GMP) and regulatory requirements.

3) Responsibilities

Operators: Responsible for using the validated detergents and cleaning agents according to the SOP and ensuring that they follow the correct concentration and application procedures.
Quality

Assurance (QA): Ensures that the validation of detergents and cleaning agents is conducted in accordance with this SOP and regulatory requirements. QA is responsible for reviewing and approving validation protocols, reports, and ensuring that deviations are addressed.
Production Supervisors: Oversee the validation process, ensuring that operators follow the procedures for testing and validating detergents and cleaning agents.
Validation Team: Responsible for developing validation protocols, conducting tests to evaluate cleaning effectiveness, and analyzing results to ensure detergents and cleaning agents meet required standards.
R&D Department: Ensures that any new detergents or cleaning agents are thoroughly tested and validated before being introduced into the cleaning process.
Maintenance Personnel: Ensures that the equipment used for cleaning is properly calibrated and maintained to achieve optimal cleaning performance with the validated cleaning agents.

4) Procedure

The following steps should be followed for validating detergents and cleaning agents:

1. Selection of Detergents and Cleaning Agents:
1.1 Review the available detergents and cleaning agents, considering their compatibility with the materials used in manufacturing equipment and their ability to remove specific types of residues (e.g., APIs, excipients, microbial contamination).
1.2 Ensure that the detergents and cleaning agents meet the required safety and regulatory standards and are non-toxic and non-corrosive when used as directed.
1.3 Select appropriate cleaning agents based on their effectiveness, cost, and ease of use in the manufacturing environment.
1.4 Document the selection process, including any justifications for choosing a particular detergent or cleaning agent.

2. Validation Protocol Development:
2.1 Develop a validation protocol that outlines the validation objectives, methods, and criteria for evaluating the cleaning agents’ performance.
2.2 The protocol should include the following components: cleaning agent concentration, cleaning time, temperature, application method, and the type of residues to be removed.
2.3 Define acceptable limits for residue levels, including APIs, excipients, cleaning agent residues, and microbial contamination.
2.4 Identify and document the surfaces and equipment to be cleaned, and determine the sampling points for residue testing.

3. Testing of Detergents and Cleaning Agents:
3.1 Test the detergents and cleaning agents under typical cleaning conditions in the manufacturing environment to determine their cleaning effectiveness.
3.2 Perform cleaning efficacy tests, including swab sampling, visual inspection, and microbiological testing, to assess the removal of residues.
3.3 Analyze swab samples using appropriate methods, such as High-Performance Liquid Chromatography (HPLC), for detecting residual API or excipient traces.
3.4 Ensure that the cleaning agents are effective in removing microbial contamination through microbiological testing of swab samples.
3.5 Perform these tests on a variety of equipment surfaces, such as stainless steel, glass, and plastic, to assess the cleaning agents’ effectiveness on different materials.
3.6 Document all test results, including concentrations, temperatures, test conditions, and any deviations from the expected results.

4. Performance Qualification (PQ) for Cleaning Agents:
4.1 After initial testing, perform Performance Qualification (PQ) to assess the cleaning agent’s ability to consistently remove residues across multiple cleaning cycles and different batches of product.
4.2 Verify the cleaning agents’ ability to maintain consistency in removing residues when used over extended periods and under varied conditions.
4.3 Conduct microbiological tests to ensure that the cleaning agents do not leave behind viable microbial contamination.
4.4 Test for the cleaning agents’ long-term effectiveness by performing revalidation studies periodically as per the requalification schedule.
4.5 Document the PQ results, including residue levels, microbial counts, and any corrective actions taken during testing.

5. Documentation and Reporting:
5.1 Maintain detailed records of all validation activities, including protocol development, testing, and results.
5.2 Record all test data, including batch numbers, test dates, operator initials, and cleaning agent concentrations, in a standardized format.
5.3 Ensure that the validation protocol, test results, and reports are reviewed and approved by the Quality Assurance (QA) team.
5.4 Any deviations encountered during testing should be documented and investigated, with corrective actions implemented and documented.
5.5 Prepare a final validation report summarizing the results of the cleaning agent validation, including all testing methods, residue results, and conclusions regarding the cleaning agents’ effectiveness.

6. Revalidation:
6.1 Revalidate the cleaning agents whenever there are significant changes to the manufacturing process, equipment, or cleaning procedures.
6.2 Conduct periodic revalidation studies to ensure that cleaning agents remain effective in removing residues and contaminants over time.
6.3 Document all revalidation activities, ensuring that they meet the required standards and are compliant with regulatory requirements.

5) Abbreviations

  • IQ: Installation Qualification
  • OQ: Operational Qualification
  • PQ: Performance Qualification
  • API: Active Pharmaceutical Ingredient
  • QA: Quality Assurance
  • SOP: Standard Operating Procedure
  • HPLC: High-Performance Liquid Chromatography

6) Documents

  • Cleaning Agent Selection Report
  • Cleaning Validation Protocol
  • Testing Data and Results
  • Deviation Reports
  • Final Validation Report

7) Reference

  • FDA Guidance for Industry: Equipment Cleaning and Sanitation
  • International Council for Harmonisation (ICH) Q7: Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients
  • ISO 9001: Quality Management Systems – Requirements
  • USP Chapter 1072: Cleaning and Sanitization of Manufacturing Equipment

8) SOP Version

Version 1.0 – Effective Date: DD/MM/YYYY

Annexure

Template 1: Cleaning Validation Test Record

Date Time Operator Initials Test Type (IQ/OQ/PQ) Test Results Comments
DD/MM/YYYY HH:MM Operator Name IQ/OQ/PQ Pass/Fail Comments
           

Template 2: Swab Sampling Log

Batch No. Test Date Sampling Area Residue Level Pass/Fail Operator Initials
Batch Number DD/MM/YYYY Sampling Area Residue Level Pass/Fail Operator Name
           

Template 3: Microbiological Testing Log

Batch No. Test Date Microbial Load (CFU) Pass/Fail Operator Initials
Batch Number DD/MM/YYYY Microbial Load Pass/Fail Operator Name
         