SOP Guide for Pharma

Tablets: SOP for Real-Time Monitoring of Tablet Coating Thickness – V 2.0

Tablets: SOP for Real-Time Monitoring of Tablet Coating Thickness – V 2.0

Standard Operating Procedure for Real-Time Monitoring of Tablet Coating Thickness

Department Tablet
SOP No. SOP/TAB/026/2025
Supersedes SOP/TAB/026/2022
Page No. Page 1 of 7
Issue Date 18/06/2025
Effective Date 23/06/2025
Review Date 18/06/2026

1. Purpose

This SOP outlines the procedures for real-time monitoring of tablet coating thickness during the coating process, ensuring that the applied coating is within specified limits for uniformity and quality.

2. Scope

This SOP applies to the coating process in tablet manufacturing, specifically focusing on the use of real-time monitoring tools and techniques to measure coating thickness during the application process.

3. Responsibilities

4. Accountability

The Production Manager is accountable for ensuring that real-time monitoring is implemented and that the tablet coating process is in compliance with this SOP. The QA Manager is responsible for overseeing the monitoring system and ensuring that all data is accurately recorded.

5. Procedure

5.1 Pre-Coating Setup

  1. Ensure that the tablet coating machine is set up correctly and calibrated, including all monitoring systems for real-time coating thickness measurement.
  2. Verify that the tablet pan is clean and free from contaminants to prevent any discrepancies in the coating process.
  3. Prepare the coating solution according to the formulation and ensure it is properly filtered to prevent any blockages in the spray nozzles.
  4. Ensure that the real-time monitoring system (e.g., laser or ultrasonic sensors) is calibrated and ready for operation, ensuring that accurate data on coating thickness is recorded.

5.2 Real-Time Coating Thickness Monitoring

  1. Start the tablet coating process and activate the real-time monitoring system to begin measuring the coating thickness as the tablets move through the coating pan.
  2. Continuously monitor the data provided by the coating thickness measurement system, which should record and display the coating thickness for each tablet in real-time.
  3. Adjust the spray parameters (e.g., spray rate, nozzle size, air pressure) to maintain the desired coating thickness as indicated by the real-time data.
  4. If the coating thickness exceeds the acceptable limits (typically ±10% of the target thickness), adjust the coating process immediately to bring the thickness within specification.
  5. Ensure that the real-time monitoring system logs all data, including time, batch number, tablet identification, and measured coating thickness, into the batch record (Annexure-1).

5.3 In-Process Adjustments and Corrections

  1. If deviations in coating thickness are detected, make immediate adjustments to the coating parameters such as spray speed, solution concentration, or airflow to correct the variation.
  2. After making adjustments, continue monitoring the coating thickness in real-time to ensure the adjustments have brought the coating thickness back within the acceptable range.
  3. Record all adjustments made during the process, including the reason for the adjustment and the specific changes implemented in the batch record (Annexure-2).

5.4 Final Coating Inspection

  1. Once the real-time monitoring system confirms that the coating has reached the desired thickness, perform a final visual inspection of the coated tablets to ensure uniform coating and the absence of defects such as peeling or uneven application.
  2. Measure the coating thickness on a sample of tablets using a micrometer or coating thickness gauge to verify the data from the real-time monitoring system.
  3. Document the results of the final inspection and the coating thickness measurements in the batch record (Annexure-3).

5.5 Post-Coating Process

  1. After confirming that the desired coating thickness has been achieved, allow the tablets to dry under controlled conditions, using the drying system to prevent excess moisture that could affect tablet integrity.
  2. Ensure that the drying parameters are controlled to avoid over-drying or under-drying, which could impact the coating and tablet quality.
  3. Record all drying parameters and the results of the final coating inspection in the batch record, ensuring that all quality checks are completed before the tablets proceed to the next stage in the manufacturing process.

5.6 Equipment Shutdown and Cleaning

  1. After completing the coating process, shut down the equipment following the SOP for equipment shutdown and cleaning.
  2. Ensure that the coating pan, spray nozzles, and monitoring system are thoroughly cleaned to prevent cross-contamination during the next batch.
  3. Record the cleaning activities in the equipment cleaning log (Annexure-4) and ensure that all equipment is ready for the next production run.

5.7 Documentation and Record-Keeping

  1. Ensure that all real-time monitoring data, coating thickness measurements, and adjustments are documented in the batch record (Annexure-1).
  2. Review the batch records to ensure that all process parameters are within the acceptable range and that no deviations were left unaddressed.
  3. Ensure that all records are reviewed by QA personnel and that proper documentation is maintained for regulatory compliance and audit purposes.

6. Abbreviations

7. Documents

  1. Batch Record (Annexure-1)
  2. Coating Thickness Monitoring Log (Annexure-2)
  3. Final Inspection Log (Annexure-3)
  4. Equipment Cleaning Log (Annexure-4)

8. References

9. SOP Version

Version: 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Batch Record

Batch Number Tablet Type Coating Thickness (mm) Spray Pressure (bar) Airflow Rate (m³/hr) Remarks
Batch 001 Tablet A 0.2 3 150 Within specifications
Batch 002 Tablet B 0.25 3.5 160 Adjustment applied

Annexure-2: Coating Thickness Monitoring Log

Batch Number Tablet Type Coating Thickness (mm) Time Remarks
Batch 001 Tablet A 0.2 12:00 PM Within specifications
Batch 002 Tablet B 0.25 2:00 PM Adjusted coating thickness

Annexure-3: Final Inspection Log

Batch Number Tablet Type Coating Thickness (mm) Inspection Date Remarks
Batch 001 Tablet A 0.2 12:30 PM Coating uniformity verified
Batch 002 Tablet B 0.25 2:30 PM Adjustment completed successfully

Annexure-4: Equipment Cleaning Log

Cleaning Date Equipment Cleaning Type Performed By Remarks
02/05/2025 Coating Machine Routine Cleaning John Doe Performed as per SOP
12/06/2025 Coating Machine Maintenance Cleaning Jane Smith No issues found

Revision History:

Revision Date Revision No. Revision Details Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP Creation QA Head
01/02/2025 2.0 Updated Monitoring Parameters Optimization of Coating Process QA Head