SOP for ointment viscosity testing – SOP Guide for Pharma https://www.pharmasop.in The Ultimate Resource for Pharmaceutical SOPs and Best Practices Fri, 14 Feb 2025 08:22:00 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.2 Ointments: SOP for Recording Process Observations – V 2.0 https://www.pharmasop.in/ointments-sop-for-recording-process-observations-v-2-0/ Fri, 14 Feb 2025 08:22:00 +0000 https://www.pharmasop.in/?p=8257 SOP for Recording Process Observations – V 2.0

Procedure for Recording Process Observations

Department Production/Quality Control (QC)/Quality Assurance (QA)
SOP No. SOP/Ointment/080
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to establish a standardized method for recording process observations during ointment manufacturing. Proper documentation of observations ensures process control, traceability, and compliance with Good Manufacturing Practices (GMP).

2. Scope

This SOP applies to all personnel in the Production, Quality Control (QC), and Quality Assurance (QA) departments responsible for recording and reviewing process observations during manufacturing, filling, and packaging.

3. Responsibilities

  • Production Operator: Records observations related to process conditions, material behavior, and equipment performance.
  • Production Supervisor: Ensures observations are documented accurately and any deviations are reported.
  • Quality Control Analyst: Reviews recorded observations and conducts additional testing if required.
  • Quality Assurance (QA) Personnel: Reviews and approves observation records before batch release.

4. Accountability

The Production, QC, and QA Managers are accountable for ensuring that process observations are documented accurately and reviewed as per GMP and regulatory requirements.

5. Procedure

5.1 Equipment and Materials

  • Batch Manufacturing Record (BMR)
  • Process Observation Log
  • Digital or manual recording sheets
  • Temperature, pressure, and pH monitoring devices
  • Weighing balance

5.2 Types of Process Observations

5.2.1 Raw Material Observations

  • Check and record the condition of raw materials (e.g., color, texture, packaging integrity).
  • Verify raw material identity before processing.
  • Document any discrepancies in supplier specifications.

5.2.2 Mixing Process Observations

  • Record temperature, speed, and duration of mixing.
  • Observe viscosity changes and phase separation, if any.
  • Document any unusual behaviors, such as foaming or clumping.

5.2.3 In-Process Testing Observations

  • Document pH, viscosity, and homogeneity test results.
  • Record any out-of-specification (OOS) findings and corrective actions taken.

5.2.4 Filling and Packaging Observations

  • Monitor and document filling speed, accuracy, and volume deviations.
  • Ensure proper labeling and packaging integrity.
  • Record any incidents of leaking or mislabeling.

5.3 Process Documentation Requirements

  • Observations should be recorded in real time.
  • Corrections should be made using a single-line strike-through, with initials and date.
  • Any deviations from standard parameters must be reported to the Production Supervisor.
  • Final observations should be reviewed and approved before batch release.

5.4 Corrective Actions

  • If any deviation is observed, immediately inform the supervisor.
  • Document the corrective actions taken in the Process Observation Log.
  • Ensure that affected products are held for further inspection before release.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • BMR – Batch Manufacturing Record
  • OOS – Out of Specification

7. Documents

  • Process Observation Log (Annexure-1)
  • Final Batch Observation Report (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • ICH Q8 – Pharmaceutical Development
  • USP <1163> – Quality Assurance in Pharmaceutical Compounding

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Process Observation Log

Date Batch Number Process Stage Observed Parameter Deviation (if any) Action Taken Verified By
01/02/2025 OINT-101 Mixing Temperature: 65°C None NA QA Officer
01/02/2025 OINT-101 Filling Volume: 30 g +0.5 g Machine adjusted QA Officer

Annexure-2: Final Batch Observation Report

Date Batch Number Observation Summary Corrective Actions Final Status Approved By
01/02/2025 OINT-101 Minor volume deviation corrected Machine recalibrated Approved QA Head
01/02/2025 OINT-102 Temperature fluctuation observed Verified and within limit Approved QA Head

12. Revision History:

Revision Date Revision No. Details of Revision Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP QA Head
01/02/2025 2.0 Updated SOP Format Standardization of Document QA Head
]]>
Ointments: SOP for Conducting On-the-Spot Microbial Testing – V 2.0 https://www.pharmasop.in/ointments-sop-for-conducting-on-the-spot-microbial-testing-v-2-0/ Thu, 13 Feb 2025 19:02:00 +0000 https://www.pharmasop.in/ointments-sop-for-conducting-on-the-spot-microbial-testing-v-2-0/ SOP for Conducting On-the-Spot Microbial Testing – V 2.0

Procedure for Conducting On-the-Spot Microbial Testing

Department Quality Control (QC)/Microbiology
SOP No. SOP/Ointment/079
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to define a standardized method for conducting on-the-spot microbial testing in ointment manufacturing. This procedure ensures that the product remains free from microbial contamination at critical control points.

2. Scope

This SOP applies to Quality Control (QC) and Microbiology personnel responsible for performing on-the-spot microbial tests on raw materials, in-process samples, and finished ointments.

3. Responsibilities

  • Microbiologist: Conducts microbial testing and records results.
  • QC Analyst: Collects samples and ensures proper handling.
  • Production Supervisor: Ensures adherence to microbial control measures.
  • Quality Assurance (QA) Personnel: Reviews and approves microbial test reports.

4. Accountability

The QC and QA Managers are accountable for ensuring that microbial testing is performed accurately and documented as per GMP and regulatory guidelines.

5. Procedure

5.1 Equipment and Materials

  • Sterile sampling swabs
  • Agar plates (TSA, SDA, MacConkey)
  • Petri dishes
  • Incubator (30-35°C)
  • Sterile forceps and gloves
  • Laminar airflow hood
  • Microbial testing logbook

5.2 Sampling for Microbial Testing

5.2.1 Raw Material Sampling

  • Collect raw material samples using sterile containers.
  • Test for Total Aerobic Microbial Count (TAMC) and Total Yeast and Mold Count (TYMC).

5.2.2 In-Process Sampling

  • Take samples at key process stages (e.g., mixing, filling).
  • Use swab sampling on equipment and work surfaces.

5.2.3 Finished Product Sampling

  • Randomly select filled containers for microbial testing.
  • Test for the presence of specific pathogens (Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa).

5.3 Microbial Testing Procedure

5.3.1 Total Aerobic Microbial Count (TAMC)

  • Plate the sample on TSA (Tryptic Soy Agar).
  • Incubate at 30-35°C for 48 hours.
  • Count and record colony-forming units (CFU).

5.3.2 Total Yeast and Mold Count (TYMC)

  • Plate the sample on SDA (Sabouraud Dextrose Agar).
  • Incubate at 20-25°C for 5-7 days.
  • Record fungal growth.

5.3.3 Pathogen Testing

  • Use selective media for specific pathogens.
  • Incubate at appropriate temperatures.
  • Confirm results using biochemical tests.

5.4 Acceptance Criteria

  • TAMC: Not more than 100 CFU/g.
  • TYMC: Not more than 10 CFU/g.
  • Pathogens: Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa must be absent.

5.5 Documentation

  • Record all microbial test results in the Microbial Testing Log.
  • Ensure that any deviations are documented and corrective actions taken.
  • QA personnel must review and approve test results before batch release.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • TAMC – Total Aerobic Microbial Count
  • TYMC – Total Yeast and Mold Count

7. Documents

  • Microbial Testing Log (Annexure-1)
  • Microbial Test Report (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • USP <1111> – Microbiological Examination of Nonsterile Products
  • ICH Q6A – Specifications: Test Procedures and Acceptance Criteria

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Microbial Testing Log

Date Batch Number Sample ID TAMC (CFU/g) TYMC (CFU/g) Pathogens Detected Result Verified By
01/02/2025 OINT-101 SMP-001 85 5 None Pass QA Officer
01/02/2025 OINT-102 SMP-002 92 8 None Pass QA Officer

Annexure-2: Microbial Test Report

Date Batch Number Test Type Acceptance Criteria Result Final Status Approved By
01/02/2025 OINT-101 TAMC ≤ 100 CFU/g 85 CFU/g Approved QA Head
01/02/2025 OINT-102 TYMC ≤ 10 CFU/g 8 CFU/g Approved QA Head

12. Revision History:

]]>
Ointments: SOP for Verifying Labeling Accuracy – V 2.0 https://www.pharmasop.in/ointments-sop-for-verifying-labeling-accuracy-v-2-0/ Thu, 13 Feb 2025 05:42:00 +0000 https://www.pharmasop.in/ointments-sop-for-verifying-labeling-accuracy-v-2-0/ SOP for Verifying Labeling Accuracy – V 2.0

Procedure for Verifying Labeling Accuracy

Department Quality Control (QC)/Production/Quality Assurance (QA)
SOP No. SOP/Ointment/078
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to establish a standardized method for verifying labeling accuracy in ointment packaging. Proper labeling ensures compliance with regulatory requirements and prevents mix-ups, misbranding, and incorrect product identification.

2. Scope

This SOP applies to all personnel in the Production, Quality Control (QC), and Quality Assurance (QA) departments responsible for inspecting and verifying the accuracy of labels on ointment containers before batch release.

3. Responsibilities

  • Production Operator: Ensures labels are applied correctly and match the product specifications.
  • Production Supervisor: Monitors in-process labeling verification and resolves any issues.
  • Quality Control Analyst: Conducts random label accuracy checks and records observations.
  • Quality Assurance (QA) Personnel: Reviews and approves labeling documentation before product release.

4. Accountability

The Production, QC, and QA Managers are accountable for ensuring that labeling accuracy is verified and documented as per GMP and regulatory requirements.

5. Procedure

5.1 Equipment and Materials

  • Automatic or semi-automatic labeling machine
  • Barcode scanner (if applicable)
  • Labeling specification sheet
  • Reference sample of approved label
  • Batch Manufacturing Record (BMR)
  • Label Verification Log

5.2 Pre-Labeling Checks

  • Ensure that the correct labels are used for the batch.
  • Verify label content against the approved label specification.
  • Check that the label printer is functioning correctly.
  • Perform a trial label application on a dummy container before starting production.

5.3 In-Process Labeling Verification

5.3.1 Visual Inspection

  • Inspect labels for legibility, clarity, and correctness.
  • Ensure that batch number, expiry date, and manufacturing details are printed correctly.
  • Check for smudging, misalignment, or label peeling.

5.3.2 Barcode and Serial Number Verification (if applicable)

  • Scan the barcode on randomly selected units.
  • Ensure the barcode matches the product database.
  • Verify that serialization numbers are unique and properly recorded.

5.3.3 Random Sampling

  • Collect a defined number of units (e.g., 10 per 1000 units) for label verification.
  • Cross-check label details with the approved reference sample.
  • Document any discrepancies and notify the Production Supervisor immediately.

5.4 Corrective Actions for Labeling Errors

  • If a labeling error is detected, halt the labeling process immediately.
  • Remove affected units from production.
  • Identify the root cause (e.g., printer malfunction, incorrect roll of labels).
  • Reprint and reapply labels as needed.
  • Perform additional checks before resuming production.

5.5 Acceptance Criteria

  • All printed details (batch number, expiry date, barcode, etc.) must be legible and match the BMR.
  • Labels must be applied straight, without wrinkles, air bubbles, or misalignment.
  • Any batch with more than 1% labeling defects must undergo full batch inspection.

5.6 Post-Labeling Verification

  • Perform final visual inspection of labeled units before batch release.
  • Ensure any rejected units have been properly documented and removed.
  • QA personnel must review and approve the Label Verification Log.

5.7 Documentation

  • Record all label verification results in the Label Verification Log.
  • Document all corrective actions if labeling deviations occur.
  • Ensure traceability by maintaining batch-wise records.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • BMR – Batch Manufacturing Record

7. Documents

  • Label Verification Log (Annexure-1)
  • Final Batch Labeling Report (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • USP <17> – Prescription Container Labeling
  • ICH Q8 – Pharmaceutical Development

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Label Verification Log

Date Batch Number Sample ID Checked By Defects Observed Action Taken Verified By
01/02/2025 OINT-101 SMP-001 QA Officer None Approved QA Supervisor
01/02/2025 OINT-102 SMP-002 QA Officer Smudged text Label Reprinted QA Supervisor

Annexure-2: Final Batch Labeling Report

Date Batch Number Label Verification Acceptance Criteria Result Final Status Approved By
01/02/2025 OINT-101 Checked No defects Pass Approved QA Head
01/02/2025 OINT-102 Checked No defects Pass Approved QA Head

12. Revision History:

]]>
Ointments: SOP for Ensuring Consistent Filling Volume – V 2.0 https://www.pharmasop.in/ointments-sop-for-ensuring-consistent-filling-volume-v-2-0/ Wed, 12 Feb 2025 16:22:00 +0000 https://www.pharmasop.in/ointments-sop-for-ensuring-consistent-filling-volume-v-2-0/ SOP for Ensuring Consistent Filling Volume – V 2.0

Procedure for Ensuring Consistent Filling Volume

Department Production/Quality Control (QC)/Quality Assurance (QA)
SOP No. SOP/Ointment/077
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to define the method for ensuring consistent filling volume in ointment packaging. Maintaining uniform filling volume is essential for dosage accuracy, product quality, and compliance with Good Manufacturing Practices (GMP).

2. Scope

This SOP applies to all personnel in the Production, Quality Control (QC), and Quality Assurance (QA) departments responsible for monitoring and verifying filling volume in ointment packaging.

3. Responsibilities

  • Production Operator: Ensures the filling process adheres to predefined volume specifications.
  • Production Supervisor: Monitors and verifies in-process filling volume checks.
  • Quality Control Analyst: Conducts volume accuracy tests and records observations.
  • Quality Assurance (QA) Personnel: Reviews and approves batch records for compliance.

4. Accountability

The Production, QC, and QA Managers are accountable for ensuring that filling volume consistency is maintained and documented as per regulatory requirements.

5. Procedure

5.1 Equipment and Materials

  • Automatic or semi-automatic filling machine
  • Calibrated weighing balance
  • Graduated cylinders or volumetric pipettes
  • Filling volume monitoring log
  • Batch Manufacturing Record (BMR)

5.2 Pre-Filling Checks

  • Ensure that the filling machine is calibrated according to the batch specifications.
  • Verify that the correct nozzle size is used for filling.
  • Ensure uniform temperature and viscosity of the ointment.
  • Conduct a test fill using a reference container to check the volume before starting batch production.

5.3 Monitoring Filling Volume

5.3.1 In-Process Volume Checks

  • Randomly sample filled containers at defined intervals (e.g., every 30 minutes).
  • Weigh the filled container and compare it against the target volume.
  • Alternatively, use a graduated cylinder to check volume accuracy.
  • Ensure that variation does not exceed ±5% of the target volume.

5.3.2 Adjusting Filling Machine

  • If underfilling or overfilling is detected, adjust the machine settings accordingly.
  • Document any corrective actions taken.
  • Re-check the filling volume after adjustments to ensure compliance.

5.4 Acceptance Criteria

  • Each filled container should meet the predefined volume specification (e.g., 30 g ± 1 g).
  • The filling variation should not exceed the defined acceptance limits.
  • Rejected units due to volume deviations must be documented and investigated.

5.5 Post-Filling Verification

  • Perform final volume checks before batch release.
  • Ensure that all volume-related deviations have been resolved.
  • QA personnel must review and approve batch records before shipment.

5.6 Documentation

  • Record all filling volume tests in the Filling Volume Monitoring Log.
  • Document all corrective actions if volume deviations occur.
  • Ensure traceability by maintaining batch-wise records.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • BMR – Batch Manufacturing Record

7. Documents

  • Filling Volume Monitoring Log (Annexure-1)
  • Batch Filling Report (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • USP <905> – Uniformity of Dosage Units
  • ICH Q6A – Specifications: Test Procedures and Acceptance Criteria

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Filling Volume Monitoring Log

Date Batch Number Sample ID Target Volume Observed Volume Acceptance Criteria Result Verified By
01/02/2025 OINT-101 SMP-001 30 g 29.8 g ±1 g Pass QA Officer
01/02/2025 OINT-102 SMP-002 30 g 30.2 g ±1 g Pass QA Officer

Annexure-2: Batch Filling Report

Date Batch Number Filling Volume Test Acceptance Criteria Result Final Status Approved By
01/02/2025 OINT-101 Volume Measurement 30 g ± 1 g 29.8 g Approved QA Head
01/02/2025 OINT-102 Volume Measurement 30 g ± 1 g 30.2 g Approved QA Head

12. Revision History:

Revision Date Revision No. Details of Revision Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP QA Head
01/02/2025 2.0 Updated SOP Format Standardization of Document QA Head
]]>
Ointments: SOP for Performing In-Process pH Tests – V 2.0 https://www.pharmasop.in/ointments-sop-for-performing-in-process-ph-tests-v-2-0/ Wed, 12 Feb 2025 03:02:00 +0000 https://www.pharmasop.in/ointments-sop-for-performing-in-process-ph-tests-v-2-0/ SOP for Performing In-Process pH Tests – V 2.0

Procedure for Performing In-Process pH Tests

Department Quality Control (QC)/Production
SOP No. SOP/Ointment/076
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to define the method for performing in-process pH tests during ointment manufacturing. pH testing ensures product stability, efficacy, and compliance with predefined specifications.

2. Scope

This SOP applies to all personnel in the Quality Control (QC) and Production departments responsible for in-process pH testing of ointments during manufacturing.

3. Responsibilities

  • Quality Control Analyst: Conducts in-process pH tests and records results.
  • Production Operator: Provides in-process samples for testing.
  • Production Supervisor: Ensures adherence to pH monitoring protocols.
  • Quality Assurance (QA) Personnel: Reviews and approves pH test records.

4. Accountability

The QC and QA Managers are accountable for ensuring in-process pH tests are performed and documented as per GMP and regulatory requirements.

5. Procedure

5.1 Equipment and Materials

  • Calibrated digital pH meter
  • Glass beakers (100 mL, 250 mL)
  • Magnetic stirrer (if required)
  • pH buffer solutions (pH 4.0, 7.0, and 10.0)
  • Distilled water
  • Sampling containers
  • pH Test Log

5.2 Pre-Test Preparations

  • Ensure the pH meter is calibrated using standard buffer solutions.
  • Rinse the electrode with distilled water before testing.
  • Prepare fresh ointment samples for analysis.
  • Ensure samples are maintained at the required testing temperature (typically 25°C ± 2°C).

5.3 pH Testing Procedure

5.3.1 Sample Preparation

  • Weigh an appropriate amount of ointment (e.g., 1 g – 2 g).
  • Disperse the sample in 10-20 mL of distilled water in a beaker.
  • Stir the mixture gently to create a uniform suspension.
  • Allow the mixture to stabilize for 5 minutes.

5.3.2 Measuring pH

  • Immerse the pH meter electrode into the sample.
  • Ensure the electrode is fully submerged without touching the beaker.
  • Wait for a stable reading (approximately 30-60 seconds).
  • Record the pH value in the pH Test Log.

5.4 Acceptance Criteria

  • The pH of the ointment must be within the predefined specification range (e.g., 5.5 – 7.5).
  • If the pH deviates from the acceptable range, report to the Production Supervisor immediately.
  • Adjust the formulation as required (e.g., adding buffer solutions or pH-adjusting agents).

5.5 Post-Test Procedure

  • Rinse the pH electrode with distilled water after each test.
  • Store the electrode in the recommended storage solution.
  • Ensure all pH test results are documented in the pH Test Log.
  • QA personnel must review and approve pH test reports before batch release.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • pH – Potential of Hydrogen

7. Documents

  • pH Test Log (Annexure-1)
  • Batch Release Report (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • USP <791> – pH Measurement
  • ICH Q6A – Specifications: Test Procedures and Acceptance Criteria

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: pH Test Log

Date Batch Number Sample ID pH Value Acceptance Criteria Result Verified By
01/02/2025 OINT-101 SMP-001 6.2 5.5 – 7.5 Pass QA Officer
01/02/2025 OINT-102 SMP-002 7.1 5.5 – 7.5 Pass QA Officer

Annexure-2: Batch Release Report

Date Batch Number pH Test Acceptance Criteria Result Final Status Approved By
01/02/2025 OINT-101 pH Measurement 5.5 – 7.5 6.2 Approved QA Head
01/02/2025 OINT-102 pH Measurement 5.5 – 7.5 7.1 Approved QA Head

12. Revision History:

Revision Date Revision No. Details of Revision Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP QA Head
01/02/2025 2.0 Updated SOP Format Standardization of Document QA Head
]]>
Ointments: SOP for Checking the Homogeneity of Ointment Batches – V 2.0 https://www.pharmasop.in/ointments-sop-for-checking-the-homogeneity-of-ointment-batches-v-2-0/ Tue, 11 Feb 2025 13:42:00 +0000 https://www.pharmasop.in/ointments-sop-for-checking-the-homogeneity-of-ointment-batches-v-2-0/ SOP for Checking the Homogeneity of Ointment Batches – V 2.0

Procedure for Checking the Homogeneity of Ointment Batches

Department Production/Quality Control (QC)/Quality Assurance (QA)
SOP No. SOP/Ointment/075
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to define the process for checking the homogeneity of ointment batches to ensure consistency in composition, texture, and distribution of active ingredients throughout the product.

2. Scope

This SOP applies to all personnel in the Production, Quality Control (QC), and Quality Assurance (QA) departments responsible for verifying the uniformity and homogeneity of ointment formulations during manufacturing and prior to batch release.

3. Responsibilities

  • Production Operator: Ensures the mixing process is performed according to batch manufacturing instructions.
  • Production Supervisor: Verifies that homogeneity tests are performed and documented.
  • Quality Control Analyst: Conducts laboratory tests to confirm uniform distribution of active and inactive ingredients.
  • Quality Assurance (QA) Personnel: Reviews batch records and approves batch release based on homogeneity compliance.

4. Accountability

The Production, QC, and QA Managers are accountable for ensuring that homogeneity testing is properly conducted and documented as per GMP and regulatory standards.

5. Procedure

5.1 Equipment and Materials

  • Mixing tanks with agitators
  • Viscometer
  • pH meter
  • UV-Vis spectrophotometer or HPLC
  • Glass slides and microscope (for microscopic evaluation)
  • Sampling containers
  • Batch Manufacturing Record (BMR)

5.2 Pre-Homogeneity Check Preparations

  • Ensure raw materials are weighed and mixed according to the standard formula.
  • Verify that mixing parameters (speed, time, temperature) are set correctly.
  • Confirm that the batch is within the defined temperature and viscosity limits.
  • Ensure that sampling tools and containers are sterile and suitable for use.

5.3 Homogeneity Testing Procedure

5.3.1 In-Process Homogeneity Check

  • Take samples from three different points in the mixing tank:
    • Top
    • Middle
    • Bottom
  • Compare the physical characteristics of each sample.
  • Check for color uniformity, phase separation, or presence of air bubbles.

5.3.2 Laboratory Homogeneity Tests

5.3.2.1 Active Ingredient Assay
  • Use HPLC or UV-Vis spectroscopy to check active ingredient concentration.
  • Ensure that variation among samples does not exceed ±5% of the target value.
5.3.2.2 pH Measurement
  • Measure the pH of samples taken from different sections of the batch.
  • Ensure pH consistency across all samples within an acceptable range.
5.3.2.3 Viscosity Testing
  • Measure viscosity using a viscometer to confirm uniformity.
  • Compare the viscosity of all three samples to ensure uniformity.
5.3.2.4 Microscopic Evaluation
  • Prepare slides of ointment samples and observe under a microscope.
  • Confirm uniform dispersion of particles without aggregation.

5.4 Acceptance Criteria

  • The active ingredient should be evenly distributed within ±5% of the label claim.
  • pH variation should not exceed 0.5 units across samples.
  • Viscosity differences between samples should not exceed 10%.
  • There should be no visible phase separation or air entrapment.

5.5 Documentation

  • Record all homogeneity test results in the Homogeneity Test Log.
  • Ensure all deviations and corrective actions are documented.
  • QA personnel must review and approve test reports before batch release.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • BMR – Batch Manufacturing Record
  • HPLC – High-Performance Liquid Chromatography

7. Documents

  • Homogeneity Test Log (Annexure-1)
  • Batch Release Report (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • USP <905> – Uniformity of Dosage Units
  • ICH Q6A – Specifications: Test Procedures and Acceptance Criteria

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Homogeneity Test Log

Date Batch Number Sample Location Active Ingredient (%) pH Viscosity Result Verified By
01/02/2025 OINT-101 Top 98.5% 6.3 45,000 cP Pass QA Officer
01/02/2025 OINT-101 Middle 98.8% 6.4 45,500 cP Pass QA Officer
01/02/2025 OINT-101 Bottom 98.2% 6.3 44,900 cP Pass QA Officer

Annexure-2: Batch Release Report

Date Batch Number Homogeneity Test Acceptance Criteria Result Final Status Approved By
01/02/2025 OINT-101 HPLC Assay 95% – 105% 98.5% Approved QA Head

12. Revision History:

]]>
Ointments: SOP for Ensuring Batch Uniformity in Ointments – V 2.0 https://www.pharmasop.in/ointments-sop-for-ensuring-batch-uniformity-in-ointments-v-2-0/ Tue, 11 Feb 2025 00:22:00 +0000 https://www.pharmasop.in/ointments-sop-for-ensuring-batch-uniformity-in-ointments-v-2-0/ SOP for Ensuring Batch Uniformity in Ointments – V 2.0

Procedure for Ensuring Batch Uniformity in Ointments

Department Production/Quality Control (QC)/Quality Assurance (QA)
SOP No. SOP/Ointment/074
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to establish a standardized method for ensuring batch uniformity in ointment manufacturing. Uniformity in batch production is critical for consistency, efficacy, and compliance with Good Manufacturing Practices (GMP).

2. Scope

This SOP applies to all personnel in the Production, Quality Control (QC), and Quality Assurance (QA) departments responsible for monitoring, testing, and verifying batch uniformity during ointment manufacturing.

3. Responsibilities

  • Production Operator: Ensures that all mixing and blending procedures are followed accurately.
  • Production Supervisor: Monitors batch processes and verifies uniformity checks.
  • Quality Control Analyst: Conducts physical, chemical, and microbiological tests to confirm uniformity.
  • Quality Assurance (QA) Personnel: Reviews batch records and approves release based on uniformity compliance.

4. Accountability

The Production, QC, and QA Managers are accountable for ensuring that batch uniformity is maintained and documented as per regulatory standards.

5. Procedure

5.1 Equipment and Materials

  • Mixing tanks with agitators
  • Viscometer
  • pH meter
  • Sampling containers
  • High-Performance Liquid Chromatography (HPLC) system
  • Microbiological testing kits
  • Batch Manufacturing Record (BMR)

5.2 Pre-Manufacturing Checks

  • Ensure all raw materials meet specification requirements.
  • Verify mixing equipment calibration and functionality.
  • Ensure accurate weighing and dispensing of raw materials.
  • Review Batch Manufacturing Record (BMR) for compliance.

5.3 Monitoring Batch Uniformity

5.3.1 Mixing and Blending

  • Start mixing at the defined speed and duration as per the batch process.
  • Monitor temperature and viscosity at intervals to ensure uniform blending.
  • Perform in-process sampling to check consistency.
  • Ensure that phase separation does not occur.

5.3.2 In-Process Sampling

  • Collect samples from different points in the mixing vessel.
  • Ensure sampling from the top, middle, and bottom layers.
  • Analyze pH, viscosity, and active ingredient content.

5.3.3 Testing for Uniformity

  • Perform HPLC or UV spectrophotometry for active ingredient uniformity.
  • Check for microbial contamination as per batch release requirements.
  • Ensure the final product meets viscosity and spreadability standards.

5.4 Acceptance Criteria

  • Active ingredient content must be within ±5% of the target value.
  • pH variation should not exceed 0.5 units from the defined range.
  • Viscosity should remain within predefined limits.
  • No phase separation or foreign particles should be observed.

5.5 Documentation

  • Record all uniformity test results in the Batch Uniformity Log.
  • Document all corrective actions if uniformity deviations occur.
  • QA personnel must review and approve batch records before release.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • BMR – Batch Manufacturing Record
  • HPLC – High-Performance Liquid Chromatography

7. Documents

  • Batch Uniformity Log (Annexure-1)
  • Batch Release Report (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • USP <905> – Uniformity of Dosage Units
  • ICH Q6A – Specifications: Test Procedures and Acceptance Criteria

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Batch Uniformity Log

Date Batch Number Sample Location Active Ingredient (%) pH Viscosity Result Verified By
01/02/2025 OINT-101 Top 98.5% 6.3 45,000 cP Pass QA Officer
01/02/2025 OINT-101 Middle 98.8% 6.4 45,500 cP Pass QA Officer
01/02/2025 OINT-101 Bottom 98.2% 6.3 44,900 cP Pass QA Officer

Annexure-2: Batch Release Report

Date Batch Number Uniformity Test Acceptance Criteria Result Final Status Approved By
01/02/2025 OINT-101 HPLC Assay 95% – 105% 98.5% Approved QA Head
01/02/2025 OINT-101 pH Measurement 6.0 – 6.5 6.3 Approved QA Head

12. Revision History:

]]>
Ointments: SOP for Conducting Sampling at Intervals – V 2.0 https://www.pharmasop.in/ointments-sop-for-conducting-sampling-at-intervals-v-2-0/ Mon, 10 Feb 2025 11:02:00 +0000 https://www.pharmasop.in/ointments-sop-for-conducting-sampling-at-intervals-v-2-0/ SOP for Conducting Sampling at Intervals – V 2.0

Procedure for Conducting Sampling at Intervals

Department Quality Control (QC)/Production
SOP No. SOP/Ointment/073
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to establish a systematic method for conducting sampling at defined intervals during ointment manufacturing to ensure batch consistency, quality, and compliance with regulatory standards.

2. Scope

This SOP applies to Quality Control (QC) and Production personnel involved in in-process sampling of ointments at various stages of manufacturing, including raw material processing, mixing, filling, and packaging.

3. Responsibilities

  • Quality Control Analyst: Conducts sampling, performs tests, and records results.
  • Production Operator: Provides samples at designated time intervals.
  • Production Supervisor: Ensures adherence to sampling schedules and protocols.
  • Quality Assurance (QA) Personnel: Reviews and approves sampling records.

4. Accountability

The QC and QA Managers are accountable for ensuring that interval sampling is performed correctly and documented according to GMP and regulatory requirements.

5. Procedure

5.1 Equipment and Materials

  • Sterile sampling containers
  • Sterile spatulas or pipettes
  • Labeling materials (sample tags, barcode labels)
  • Temperature and humidity monitoring devices (if required)
  • Sampling logbook or electronic system

5.2 Sampling Frequency

  • Raw Materials: Sample each batch upon receipt and before use.
  • Mixing Stage: Sample at defined intervals (e.g., every 30 minutes or as per batch record).
  • Filling Stage: Collect samples every predetermined number of filled containers.
  • Final Product: Take final samples before batch release for QC testing.

5.3 Sampling Procedure

5.3.1 Raw Material Sampling

  • Use a sterile spatula to collect a representative sample.
  • Transfer sample into a clean, labeled container.
  • Seal and document the sample in the Raw Material Sampling Log.

5.3.2 In-Process Sampling

  • Collect the sample at pre-defined intervals during manufacturing.
  • Ensure the sample is representative of the batch.
  • Record observations such as texture, color, and viscosity.
  • Store samples as per storage conditions defined in the batch record.

5.3.3 Finished Product Sampling

  • Collect samples from different locations of the batch (beginning, middle, and end).
  • Ensure that proper identification and documentation are maintained.
  • Send samples for microbiological, chemical, and physical testing.

5.4 Acceptance Criteria

  • Samples must be collected as per defined intervals.
  • No contamination or cross-contamination should be observed.
  • All samples must be labeled and stored correctly.

5.5 Documentation

  • Record all sample details in the Sampling Log.
  • Ensure traceability by maintaining batch-wise sample records.
  • QA personnel must review and approve all documentation.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • BMR – Batch Manufacturing Record

7. Documents

  • Sampling Log (Annexure-1)
  • Batch Sampling Record (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • USP <1116> – Microbiological Evaluation of Cleanrooms and Other Controlled Environments
  • ICH Q7 – Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Sampling Log

Date Batch Number Process Stage Sample ID Sampling Time Storage Condition Result Verified By
01/02/2025 OINT-101 Mixing SMP-001 10:00 AM Room Temp Pass QA Officer
01/02/2025 OINT-101 Filling SMP-002 12:00 PM Room Temp Pass QA Officer

Annexure-2: Batch Sampling Record

Date Batch Number Sampling Stage Time Interval Acceptance Criteria Result Final Status Approved By
01/02/2025 OINT-101 Mixing 30 min Homogeneous Pass Approved QA Head
01/02/2025 OINT-101 Final Product End of batch Meets specs Pass Approved QA Head

12. Revision History:

Revision Date Revision No. Details of Revision Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP QA Head
01/02/2025 2.0 Updated SOP Format Standardization of Document QA Head
]]>
Ointments: SOP for Checking Temperature During Manufacturing – V 2.0 https://www.pharmasop.in/ointments-sop-for-checking-temperature-during-manufacturing-v-2-0/ Sun, 09 Feb 2025 21:42:00 +0000 https://www.pharmasop.in/ointments-sop-for-checking-temperature-during-manufacturing-v-2-0/ SOP for Checking Temperature During Manufacturing – V 2.0

Procedure for Checking Temperature During Manufacturing

Department Production/Quality Control (QC)/Engineering
SOP No. SOP/Ointment/072
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to define the method for monitoring and controlling temperature during the manufacturing process to ensure product consistency, stability, and compliance with GMP standards.

2. Scope

This SOP applies to all personnel in the Production, Quality Control (QC), and Engineering departments responsible for monitoring and verifying temperature conditions during the manufacturing process.

3. Responsibilities

  • Production Operator: Monitors and records temperature at specified intervals.
  • Production Supervisor: Ensures that manufacturing processes are carried out at the required temperatures.
  • Quality Control Analyst: Reviews temperature records and verifies compliance with batch specifications.
  • Engineering Team: Maintains and calibrates temperature monitoring devices.

4. Accountability

The Production and Quality Control Managers are accountable for ensuring that temperature monitoring is conducted accurately and documented as per regulatory and GMP standards.

5. Procedure

5.1 Equipment and Materials

  • Calibrated digital thermometers
  • Temperature sensors (PT100, RTD, or thermocouples)
  • Data loggers (if applicable)
  • Batch Manufacturing Record (BMR)
  • Temperature monitoring logs
  • Calibration tools

5.2 Pre-Manufacturing Checks

  • Ensure that temperature sensors and thermometers are properly calibrated.
  • Verify that heating and cooling systems are functional.
  • Confirm that the required temperature settings are defined in the batch manufacturing record (e.g., 60°C – 75°C for melting phase).
  • Ensure that materials are at the appropriate starting temperature before processing.

5.3 Monitoring Temperature During Manufacturing

5.3.1 Setting Temperature Conditions

  • Set temperature parameters based on the process stage (e.g., heating, cooling, or storage).
  • Ensure temperature remains within the defined range during each stage.
  • Document any temperature fluctuations and corrective actions taken.

5.3.2 Continuous Temperature Monitoring

  • Record temperature at defined intervals (e.g., every 15 minutes).
  • Ensure temperature stability is maintained throughout the batch process.
  • If temperature deviates from specifications, inform the Production Supervisor immediately.

5.4 Critical Temperature Control Points

  • Melting Stage: Maintain temperature to ensure complete dissolution of waxes and emulsifiers.
  • Mixing Stage: Ensure temperature is optimal for uniform blending.
  • Cooling Phase: Control cooling rate to prevent crystallization or phase separation.

5.5 Temperature Adjustment Guidelines

  • If temperature drops below the lower limit, increase heating cautiously.
  • If temperature exceeds the upper limit, reduce heating or initiate cooling.
  • Ensure slow and controlled temperature changes to prevent formulation instability.

5.6 Post-Manufacturing Verification

  • Check final product temperature before storage or packaging.
  • Verify batch temperature records against defined specifications.
  • Ensure all deviations and corrective actions are documented.

5.7 Documentation

  • Record all temperature readings in the Temperature Monitoring Log.
  • Document corrective actions taken in case of deviations.
  • QA personnel must review and approve the log before batch release.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • RTD – Resistance Temperature Detector
  • BMR – Batch Manufacturing Record

7. Documents

  • Temperature Monitoring Log (Annexure-1)
  • Batch Manufacturing Record (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • ICH Q8 – Pharmaceutical Development
  • USP <1118> – Monitoring Devices – Time, Temperature, and Humidity

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Temperature Monitoring Log

Date Batch Number Time Process Stage Set Temperature (°C) Observed Temperature (°C) Result Verified By
01/02/2025 OINT-101 10:00 AM Melting 70°C 70.2°C Pass QA Officer
01/02/2025 OINT-101 10:30 AM Cooling 40°C 39.8°C Pass QA Officer

Annexure-2: Batch Manufacturing Record

Date Batch Number Process Stage Target Temperature (°C) Actual Temperature (°C) Final Status Approved By
01/02/2025 OINT-101 Primary Mixing 65°C 64.9°C Approved QA Head
01/02/2025 OINT-101 Final Cooling 30°C 30.1°C Approved QA Head

12. Revision History:

]]>
Ointments: SOP for Monitoring Mixing Speeds – V 2.0 https://www.pharmasop.in/ointments-sop-for-monitoring-mixing-speeds-v-2-0/ Sun, 09 Feb 2025 08:22:00 +0000 https://www.pharmasop.in/ointments-sop-for-monitoring-mixing-speeds-v-2-0/ SOP for Monitoring Mixing Speeds – V 2.0

Procedure for Monitoring Mixing Speeds

Department Production/Quality Control (QC)/Engineering
SOP No. SOP/Ointment/071
Supersedes V 1.0
Page No. Page X of Y
Issue Date [Insert Issue Date]
Effective Date [Insert Effective Date]
Review Date [Insert Review Date]

1. Purpose

The purpose of this Standard Operating Procedure (SOP) is to define a standardized approach for monitoring mixing speeds during ointment manufacturing. Proper mixing speed control ensures uniformity, homogeneity, and consistency of the final product.

2. Scope

This SOP applies to all personnel in the Production, Quality Control (QC), and Engineering departments responsible for setting, monitoring, and verifying mixing speeds in ointment manufacturing.

3. Responsibilities

  • Production Operator: Monitors and records mixing speeds as per the batch manufacturing record (BMR).
  • Production Supervisor: Verifies and ensures that mixing speeds comply with standard operating conditions.
  • Quality Control Analyst: Checks product homogeneity and consistency to validate the impact of mixing speed.
  • Engineering Team: Maintains and calibrates mixing equipment to ensure proper functioning.

4. Accountability

The Production and Quality Control Managers are accountable for ensuring that mixing speeds are maintained, monitored, and documented as per regulatory and GMP standards.

5. Procedure

5.1 Equipment and Materials

  • Mixing tanks with variable speed control
  • Digital tachometer (if applicable)
  • Mixing speed monitoring logs
  • Batch Manufacturing Record (BMR)
  • Calibration tools for speed verification

5.2 Pre-Mixing Checks

  • Ensure that the mixing vessel and agitator are clean and free from residues.
  • Check that the equipment is calibrated and in working condition.
  • Verify the speed setting range as per the batch manufacturing record (e.g., 100 – 500 RPM).
  • Ensure that raw materials are correctly weighed and ready for mixing.

5.3 Monitoring Mixing Speeds

5.3.1 Setting Mixing Speeds

  • Set the initial mixing speed as per batch requirements.
  • Gradually increase the speed as needed to achieve uniform mixing.
  • Observe any changes in viscosity or foaming and adjust accordingly.

5.3.2 Continuous Speed Monitoring

  • Record mixing speed at defined intervals (e.g., every 15 minutes).
  • Ensure that speed fluctuations are within acceptable limits.
  • If speed deviations occur, document and take corrective actions.

5.4 Speed Adjustment Guidelines

  • If the mixture is too thick, increase speed gradually.
  • If excessive foaming occurs, reduce speed and use defoaming agents if required.
  • Ensure speeds are within optimal shear stress limits to prevent ingredient degradation.

5.5 Post-Mixing Verification

  • Check the final homogeneity of the batch.
  • Perform a viscosity test to confirm consistency.
  • Ensure that no unmixed particles or phase separation are present.

5.6 Documentation

  • Record all mixing speed readings in the Mixing Speed Log.
  • Document any speed adjustments made during processing.
  • QA personnel must review and approve the log before batch release.

6. Abbreviations

  • GMP – Good Manufacturing Practices
  • QA – Quality Assurance
  • QC – Quality Control
  • RPM – Revolutions Per Minute

7. Documents

  • Mixing Speed Log (Annexure-1)
  • Batch Manufacturing Record (Annexure-2)

8. References

  • WHO GMP Guidelines for Pharmaceutical Manufacturing
  • ICH Q8 – Pharmaceutical Development
  • USP <1151> – Pharmaceutical Dosage Forms

9. SOP Version

Version 2.0

10. Approval Section

Prepared By Checked By Approved By
Signature
Date
Name
Designation
Department

11. Annexures

Annexure-1: Mixing Speed Log

Date Batch Number Time Speed (RPM) Observed Consistency Result Verified By
01/02/2025 OINT-101 10:00 AM 250 Homogeneous Pass QA Officer
01/02/2025 OINT-101 10:30 AM 300 Foaming observed Adjusted QA Officer

Annexure-2: Batch Manufacturing Record

Date Batch Number Mixing Stage Target Speed (RPM) Actual Speed (RPM) Final Status Approved By
01/02/2025 OINT-101 Primary Mixing 250 250 Approved QA Head
01/02/2025 OINT-101 Final Homogenization 300 295 Approved QA Head

12. Revision History:

Revision Date Revision No. Details of Revision Reason for Revision Approved By
01/01/2024 1.0 Initial Version New SOP QA Head
01/02/2025 2.0 Updated SOP Format Standardization of Document QA Head
]]>